948 resultados para Third generation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current research and practice related to the first year experience (FYE) of commencing higher education students are still mainly piecemeal rather than institution-wide with institutions struggling to achieve cross-institutional integration, coordination and coherence of FYE policy and practice. Drawing on a decade of FYE-related research including an ALTC Senior Fellowship and evidence at a large Australian metropolitan university, this paper explores how one institution has addressed that issue by tracing the evolution and maturation of strategies that ultimately conceptualize FYE as “everybody's business.” It is argued that, when first generation co-curricular and second generation curricular approaches are integrated and implemented through an intentionally designed curriculum by seamless partnerships of academic and professional staff in a whole-of-institution transformation, we have a third generation approach labelled here as transition pedagogy. It is suggested that transition pedagogy provides the optimal vehicle for dealing with the increasingly diverse commencing student cohorts by facilitating a sense of engagement, support and belonging. What is presented here is an example of transition pedagogy in action.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel third-generation biosensor for hydrogen peroxide (H2O2) was developed by self-assembling gold nanoparticles to hollow porous thiol-functionalized poly(divinylbenzene-co-acrylic acid) (DVB-co-AA) nanospheres. At first, a cleaned gold electrode was immersed in hollow porous thiol-functionalized poly(DVB-co-AA) nanosphere latex to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups of the nanospheres. Finally, horseradish peroxidase (HRP) was immobilized on the surface of the gold nanoparticles. The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The resulting biosensor showed a wide linear range of 1.0 mu M-8.0 mM and a detection limit of 0.5 mu M estimated at a signal-to-noise ratio of 3. Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method for fabrication of horseradish peroxidase (HRP) biosensor has been developed by self-assembling gold nanoparticles on thiol-functionalized poly(styrene-co-acrylic acid) (St-co-AA) nanospheres. At first, a cleaned gold electrode was immersed in thiol-functionalized poly(St-co-AA) nanosphere latex prepared by emulsifier-free emulsion polymerization of St with AA and function with dithioglycol to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups. Finally, horseradish peroxi- dase was immobilized on the surface of the gold nanoparticles. The sensor displayed an excellent electrocatalytical response to reduction of H2O2 without the aid of an electron mediator. The sensor was highly sensitive to hydrogen peroxide with a detection limit of 4.0 mumol l(-1), and the linear range was from 10.0 mumol l(-1) to 7.0 mmol l(-1). The biosensor retained more than 97.8% of its original activity after 60 days of use. Moreover, the Studied biosensor exhibited good current repeatability and good fabrication reproducibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method for fabrication of horseradish peroxidase biosensor has been developed by self-assembling gold nanoparticles to a thiol-containing sol-gel network. A cleaned gold electrode was first immersed in a hydrolyzed (3-mercaptopropyl)-trimethoxysilane (MPS) sol-gel solution to assemble three-dimensional silica gel, and then gold nanoparticles were chemisorbed onto the thiol groups of the sol-gel network. Finally, horseradish peroxidase (HRP) was adsorbed onto the surface of the gold nanoparticles. The distribution of gold nanoparticles and HRP was examined by atomic force microscopy (AFM). The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The performance and factors influencing the performance of the resulting biosensor were studied in detail. The resulting biosensor exhibited fast amperometric response (2.5 s) to H2O2. The detection limit of the biosensor was 2.0 mumol L-1, and the linear range was from 5.0 mumol L-1 to 10.0 mmol L-1. Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Data obtained during routine diagnosis of human T-cell lymphotropic virus type 1 (HTLV-1) and 2 (HTLV-2) in ""at-risk"" individuals from Sao Paulo, Brazil using signal-to-cutoff (S/C) values obtained by first, second, and third generation enzyme immunoassay (EIA) kits, were compared. The highest S/C values were obtained with third generation EIA kits, but no correlation was detected between these values and specific antibody reactivity to HTLV-1, HTLV-2, or untyped HTLV (p = 0.302). In addition, use of these third generation kits resulted in HTLV-1/2 false-positive samples. In contrast, first and second generation EIA kits showed high specificity, and the second generation EIA kits showed the highest efficiency, despite lower S/C values. Using first and second generation EIA kits, significant differences in specific antibody detection of HTLV-1, relative to HTLV-2 (p = 0.019 for first generation and p < 0.001 for second generation EIA kits) and relative to untyped HTLV (p = 0.025 for first generation EIA kits), were observed. These results were explained by the composition and format of the assays. In addition, using receiver operating characteristics (ROC) analysis, a slight adjustment in cutoff values for third generation EIA kits improved their specificities and should be used when HTLV ""at-risk"" populations from this geographic area are to be evaluated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A previous study conducted in guinea pigs suggested that ingestion of diets high in EPA and DHA may result in suboptimal retinal function. The aim of the present study was to evaluate retinal function in pigmented (Long-Evans) rats, raised to a third generation on diets that were either deficient in n-3 PUFA or adequate (with the addition of DHA). Electroretinographic assessment employed full-field white flash stimulation. Photoreceptor responses were evaluated in terms of peak amplitudes and implicit times (a-wave, b-wave), intensity-response functions (Naka-Rushton), and the parameters of a model of transduction (P3). Retinal phospholipid FA composition was measured by capillary GLC. DHA levels were reduced by 55% in n-3-deficient animals compared with the n-3-adequate group, whereas the levels of docosapentaenoic acid n-6 were 44 times higher in n-3-deficient animals. The level of arachidonic acid was marginally higher (12.8%) in n-6-adequate animals. The n-3-deficient animals exhibited significantly reduced retinal sensitivity (σ and S values were both affected by 0.29 log units) and increased b-wave implicit times compared with those fed the n-3-adequate diet. These data suggest that n-3 PUFA are required for development of retinal sensitivity, more so than other indices of retinal function assessed by current methods, such as maximal response amplitude. However, the benefit for retinal function of adding preformed DHA to diets already replete in n-3 PUFA remains unclear.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research investigated responses of grandchildren of Holocaust survivors ("third generation") to Holocaust video-testimony. The analysis revealed that video-testimony can transmit memories of survival experiences to viewers, enabling them to "work through" their positions as witnesses and make active decisions relating to remembrance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Test procedures and their accuracy in determining critical fall height (CFH) on sporting grounds are paramount to player safety. The procedure currently adopted for synthetic turf in Australian football [1] consists of four consecutive drops at various drop heights at three test locations on the sample. The quantity and packing of the infill in third-generation turf and the pooling effect of the rubber particles with consecutive drops suggests that the current standard protocol may need re-assessment. Therefore, the purpose of this pilot study was to investigate whether current methods of testing for CFH are appropriate for third-generation synthetic turf or whether an alternative or adapted method needs to be developed. CFH was measured, using a HISUN Uniaxe-II Impact Tester, on 12 combinations of synthetic turf samples (four different products with three shock pad options). Three conditions were investigated on each sample; the existing protocol; an alternative 12 single-drop protocol and four single drops from the CFH determined from the existing protocol. A significant difference was found for both absolute and percentage difference between the existing and 12 single-drop protocol, with p = 0.001 and t = 4.33 and p < 0.001 and t = 6.03, respectively. There was also a significant difference between the CFH reached with and without a shock pad for both the existing protocol and the 12 single-drop protocol. The results of this pilot study demonstrate that differences do occur with alterations to the existing protocol and highlight the need for a more detailed characterisation of testing methods on third-generation synthetic turf and the response of surfaces to them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We argue that the masses of the first and third fermionic generations, which are respectively of the order of a few MeV up to a hundred GeV, originate from a dynamical symmetry breaking mechanism leading to masses of the order alphamu, where alpha is a small coupling constant, and mu, in the case of the first fermionic generation, is the scale of the dynamical quark mass (approximate to250 MeV). For the third fermion generation mu is the value of the dynamical techniquark mass (approximate to250 GeV). We discuss how this possibility can be implemented in a technicolor scenario, and how the mass of the intermediate generation is generated.